The development of a preventive medicine is our mission

We hope our investigation leads to the lifesaving of your loved ones

Medical technology keeps always advancing. Sadly, it is a fact that disease keeps evolving too.
Our mission is to contribute to people who request a healthy living by our technology, and to investigate the field of the preventive medicine.
We do our best to the research and development of the diagnostic product that leads to the earlier detection of disease,
always work hard at the self-study, and contribute to the development of a preventive medicine.
Until now and in the future, we sincerely face research and development that will lead to lifesaving of loved ones.

Q-may Laboratory Corporation is
a pioneer in blood coagulation reagents.

Our test kits, including the blood coagulation-related reagent "Factor Auto ® Series",
have been highly evaluated by the introduction destinations in all aspects
such as performance, stability, and cost, surpassing the products of major manufacturers.
In the future, we will not only develop and provide new products,
but also work on customization to further improve the performance of products.
While communicating with doctors and others who are active in the forefront of medical care,
we will be firmly involved in diseases with few cases and
medical fields where research is difficult.
We aim to be a group with professional knowledge and skills.

Products

Our products are supported and trusted by many medical professionals.
We respond to on-site needs with our in-house integrated production for in vitro diagnostic reagents.
We have multiple bases (headquarters, factories, laboratories),
and all processes from antibody production to commercialization are carried out by group companies.
Taking advantage of the lightness of the footwork and the closeness of the distance to the customer,
we flexibly support "manufacturing of OEM (Original Equipment Manufacturer ) products ".

In Vitro Diagnostics

  • Factor Auto D-dimer Factor Auto D-dimer

    Fibrin degradation product (D-dimer) kit
    Factor Auto D-dimer

    Latex immunoassay for the quantitative determination of D-dimer in plasma

    Package

    R1 11 mL x 2 / R2 6 mL x 1

    Expiration date

    24 months

    Storage

    2 ~ 8 degrees Celsius

    • Characteristics

      ・Factor Auto D-dimer reacts with all molecular species of cross-linked fibrin degradation products with similar affinity.
      ・Comprehensive measurement range (0.5~80 μg/mL) & High linearity (80 μg/mL)
      ・Calibration is available for Just Only One Time when the lot number of reagent is changed.
      ・Expiration date is for two years. Good reproducibility even if low concentration range.

    • Related Products

      Factor Auto D-dimer Calibrator*
      Multiple Sera N/A (Control for Factor Auto D-dimer)*
      * Not an in vitro diagnostic product in Japan.

  • Factor Auto P-FDP Factor Auto P-FDP

    Fibrin/fibrinogen degradation product (FDP) kit
    Factor Auto P-FDP

    Latex immunoassay for the quantitative determination of FDP in plasma or serum

    Package

    R1 11 mL x 2 / R2 6 mL x 1

    Expiration date

    24 months

    Storage

    2 ~ 8 degrees Celsius

    • Characteristics

      ・ Factor Auto P-FDP reacts with all molecular species of D-dimer and FgDP with similar affinity.
      ・ Comprehensive measurement range (2.5~130 μg/mL) & High linearity (80 μg/mL)
      ・Calibration is available for Just Only One Time when the lot number of reagent is changed.
      ・Expiration date is for two years.
      ・Measured value is not reversed between P-FDP and D-dimer.
      ・Both plasma and serum are available for Factor Auto P-FDP.
      ・ Factor Auto is available for various analytical instruments

    • Related Products

      Factor Auto P-FDP Calibrator*
      Multiple Sera N/A (Control for Factor Auto P-FDP)*
      * Not an in vitro diagnostic product in Japan.

  • Factor AutoⅡ FX-Ⅲ-M Factor AutoⅡ FX-Ⅲ-M

    Coagulation Factor XIII kit
    Factor AutoⅡ FX-Ⅲ-M

    Latex immunoassay for the quantitative determination of blood coagulation factor XIII in plasma

    Package

    R1 11 mL x 2 / R2 6 mL x 1

    Expiration date

    18 months(Due to be extended for 24 months)

    Storage

    2 ~ 8 degrees Celsius

    • Characteristics

      ・LTIA method to detect Factor XIII subunit A2 antigen quantitatively with one kind of Mouse monoclonal FXIII-A antibody ( the first in the world )
      ・Comprehensive measurement range (5~140 %) & High stability
      ・Calibration is available for Just Only One Time when the lot number of reagent is changed.
      ・Good stability after opening the bottle
      ・Factor Auto is available for various analytical instruments.

    • Related Products

      Factor Auto FX-Ⅲ-M Calibrator*
      Multiple Sera N/A (Control for Factor AutoⅡ FX-Ⅲ-M)*
      * Not an in vitro diagnostic product in Japan.

  • Factor Auto Fibrinogen Factor Auto Fibrinogen

    Fibrinogen(Antigen) kit
    Factor Auto Fibrinogen

    Latex immunoassay for the quantitative determination of Fibrinogen in plasma

    Package

    R1 11 mL x 2 / R2 7 mL x 1

    Expiration date

    24 months

    Storage

    2 ~ 8 degrees Celsius

    • Characteristics

      ・ Latex reagent using mouse monoclonal antibodies
      ・Fibrin / fibrinogen degradation products and anticoagulant do not cross-react with this antibody.
      ・Wide range (50~800 mg/mL)

    • Related Products

      Factor Auto Fibrinogen Calibrator*
      Factor Auto Fibrinogen Control*
      * Not an in vitro diagnostic product in Japan.

In Vitro Test For Animal

In Vitro Test For Animal

  • Tierlis D-dimer Tierlis D-dimer

    Feline & Canine D-dimer kit
    Tierlis D-dimer

    Fibrin degradation product (D-dimer) kit for feline and canine.
    Latex immunoassay for the quantitative determination of D-dimer in plasma

    Package

    R1 11 mL x 2 / R2 6 mL x 1

    Expiration date

    24 months

    Storage

    2 ~ 8 degrees Celsius

  • Tierlis P-FDP Tierlis P-FDP

    Feline & Canine FDP kit
    Tierlis P-FDP

    Fibrin/fibrinogen degradation product (FDP) kit for feline and canine
    Latex immunoassay for the quantitative determination of FDP in plasma or serum

    Package

    R1 11 mL x 2 / R2 6 mL x 1

    Expiration date

    24 months

    Storage

    2 ~ 8 degrees Celsius

  • Tierlis CRP Tierlis CRP

    Canine CRP kit
    Tierlis CRP

    C-Reactive Protein (CRP) kit for canine
    Latex immunoassay for the quantitative determination of CRP in plasma or serum

    Package

    R1 11 mL x 2 / R2 6 mL x 1

    Expiration date

    24 months

    Storage

    2 ~ 8 degrees Celsius

  • Tierlis SAAr Tierlis SAA

    Feline SAA kit
    Tierlis SAA

    Serum Amyloid A Protein (SAA) kit for feline
    Latex immunoassay for the quantitative determination of SAA in plasma or serum

    Package

    R1 11 mL x 2 / R2 6 mL x 1

    Expiration date

    24 months

    Storage

    2 ~ 8 degrees Celsius

Company Information

Company name

Q-may Laboratory Corporation

CEO , President

Yasuo Magari Ph.D.

Capital

13 million Yen

Established

24 May,1991

Business

Manufacture and distribution of in vitro diagnostics
Design, development, and manufacture of polyclonal and monoclonal antibodies
Development of medical equipment
Development and manufacture of raw materials
Manufacture and distribution of colloidal gold particles

Permission/Certification

Manufacture of in vitro diagnostics, ISO 13485 certification obtained for manufacture and distribution
Under application for manufacture and distribution of medical equipment
Under application for veterinary in vitro diagnostics

Technology

ELISA
Separation and purification
Cell culture
Immuno-Chromatography
Polyclonal antibody manufacture
Monoclonal antibody manufacture

Location

Head Office
8-37, Hanazono 2-chome, Oita-shi, Oita, Japan 870-0846
TEL:+81-97-545-5051

Taketa Factory
1116 Miyake, Taketa-City, Oita, Japan 878-0007
TEL:+81-974-63-3221

Beppu Satellite Lab
6-6-8 Ishigaki-Higashi , Beppu-City ,Oita ,Japan 874-0919

Tokyo Sales Office
402, Morita Bldg Nishiikebukuro, 11-15, Takamatsu 1-chome, Toshima-ku, Tokyo, Japan 171-0042
TEL:+81-3-5829-8631